Why the computer room should be used antistatic mobile floor

From;    Author:Stand originally
To big medium or small computer computer room, to prevent electrostatic the bad influence to computer room equipment, must consider installation to use antistatic mobile floor. Because it offerred the following advantage:
1, make install simplification, after be, the change of plant layout and augment provided bigger flexibility.
2, the equipment inside the computer room can be passed antistatic the electric link that freedom has below the floor, facilitate lay and safeguard, make a computer room neat and beautiful.
3, it can protect line of all sorts of cable, electrical wiring, data and electrical outlet, make its are not damaged bad.
4, the static warehouse pressing wind that the computer room can use the space below the floor to serve as air conditioning, acquire satisfactory air current organization. No matter computer equipment is installed in what position, can pass antistatic the air after a place with a draught of mobile floor gets air conditioning.
5, the maintenance that is helpful for equipment bottom, safeguard.
6, disappear appears besides cable the harm to human body.
7, can use antistatic of mobile floor adjustable quality, those who remove true ground is rough degree, make sure the integral level of computer room ground is spent.
8, can make discharge of leakage of electrostatic carry on one's shoulder reachs the ground, reflex electromagnetism radiate.


How to choose antistatic floor?

Choose in computer room construction antistatic mobile floor should notice the following:
1, need well and truly computer room to build place to need above all antistatic the gross area of the floor (or piece several) reach all sorts of fittings (the standard deserves to compare 1 : 3.5, 1: The amount of 5.5) , take superabundant amount, lest cause waste or shortage.
2, production of place of sufficient understanding manufacturer is antistatic the breed of the floor and quality, and all sorts of specifications index. Antistatic the specifications of the floor basically points to its machinery function and electric function. Mechanical function basically considers its carrying capacity, wearability. whole antistatic floor installation is being built receive the joist bridge that rise to go up, mix is even antistatic after the floor, its carrying capacity should achieve even load to be more than 1000kg/m2, antistatic the concentration of any place on the floor load should be more than 300kg, the to load that is 6cm in the diameter bearings on the dot when the load of 300kg, bending quantity should be less than 2mm, do not have permanent be out of shape. Adjustable prop up should bear the perpendicular bear of 1000kg above, and the wear-resisting with board due and particular face brushs a gender. Electric function basically is systematic resistor, surface resistor. Its system resistor should be 106Ω-109Ω , 21±1.5 ℃ is in temperature, relative humidity is 30% when, antistatic the electrostatic voltage of the floor should under 2500V, exterior resistance should be 106Ω-109Ω .